range
guide
Commercial & Industrial Boilers
& Radiators
www.idealcommercialboilers.com
Boilers
Condensing
icos HE
4
W
5
plus II
6
xtra
7
Concord CXC
8
GT Condenser
9
Gas Atmospheric
Concord CXA/H S/H
10
Concord Modular
11
Concord CXSi/H
12
Concord ES/H
13
High Efficiency
Super Series 4
14
Super Plus
15
Pressure Jet
Buccaneer GTE
16
Falcon GTS
17
Harrier GTE
18
Viceroy GT
19
Viscount GTE
20
Vanguard L
21
Radiators
Stelrad Radiators
22
Traditional
Elite
24
Compact
25
Low Surface Temperature
LST Standard
26
LST Plus
27
Specifier Range
Style
28
Planar
29
Concord
30
Radiator Options
31
2
contents
Ideal Boilers
Ideal Boilers is one of the most respected names in the UK Commercial and
Domestic heating industry. We design and develop ranges to suit the ever
changing UK marketplace. With the market's continued move towards
condensing products, Ideal launched the condensing range.
The recent addition of the
xtra maintains Ideal's position as the
market leading supplier in the Commercial and Industrial boiler sector.
The Commercial Heating Team
As industry leaders Ideal Boilers and Stelrad Radiators are committed to
ensuring that all products are engineered to the highest standards.
To support our products we have a comprehensive service department who
can supply you with in-depth product knowledge and system advice which
will ensure that your heating will run efficiently and will increase the
lifespan of our products.
3
Contact Numbers
Sales
Tel:
01482 498690
Fax:
01482 498621
Technical
Tel:
01482 498376
Fax:
01482 498621
Training
Tel:
01482 498432
Fax:
01482 498605
email: commercial_heating@idealboilers.com
Website
Our newly designed website contains useful information including details of
training courses, product information and literature, merchant stockists,
a background to Part L2, contact information and many more features.
You will find the website located at:
www.idealcommercialboilers.com
4
condensing
icos HE
30 + 36kW
·
Wall mounted
·
Robust cast aluminium heat exchanger
·
Compact
·
Easy to install and service
·
Modulating output down to 10.4kW
·
Wide range of flue options
·
Optional remotely mountable user controls
Model 30
36
Boiler Output (condensing) 50/30°C
11.4 - 32.8
11.4 - 39.8
Boiler Output (non-condensing) 80/60°C
10.4 - 30.1
10.4 - 37.0
Height
645
Width
450
Depth
410
Flow/Return Connections (mm)
28
Gas Inlet (BSP)
RC
1
/
2
"
Flue Size (mm)
Concentric
60/100
60/100
Twin Pipe
80/80
80/80
Maximum Working Pressure (bar)
3
Water Content (L)
4.7
4.7
Approx Dry Weight (kg)
52.6
52.6
Top (mm)
165
Below (mm)
150
Left (mm)
15
Right (mm)
15
Front (mm)
450
Condensate Drain (mm)
21.5
General Data icos HE (30 + 36)
Boiler
Clearances
Option Kits
Boiler
icos HE 30 + 36
Remote user control kit
Stand off kit
Syphon kit
Condensate pump kit
5
·
Natural gas and propane
·
Single unit or modular configuration,
wall or frame mounted
·
Robust cast aluminium heat exchanger
·
Easy to install and service
·
Simple UK voltage system controls wiring
·
Modulating output down to 13kW
·
Wide range of flue options
Model W45
W45P
W60
W60P
W80
W80P
Boiler output (condensing)
13.9 - 46.9
13.7 - 45.9
13.9 - 62.3
13.6 - 60.6
21.3 - 82.7
20.7 - 80.0
50/30°C
Boiler output (non-condensing)
12.6 - 43.7
12.6 - 58.9
19.5 - 78.2
80/60°C
Height
900
Width
540
540
540
540
650
650
Depth
500
Flow/Return Connections (BSP)
R1
1
/
4
Gas Inlet (mm)
22
Flue Size (mm)
80/125 & 100/150
80/125 & 100/150
100/150
Maximum Working Pressure (bar)
4
Water Content (L)
8
8
8
8
10
10
Approx Dry Weight (kg)
87
87
88
88
101
101
Top (mm)
dependant on flue
Below (mm)
300
Left (mm)
50
Right (mm)
50
General Data
W (45 - 80)
Boiler
Clearances
W
45 - 80kW
Option Kits
Boiler
W
Modulating sequencer kit
Programmable room thermostat kit
Control interface kit
Outside sensor kit
Tank sensor kit
Remote indication kit
Hours run meter(s)
*
BMS (0-10V) kit
Pump kit
Multi boiler frame and header kits
*Provided as standard
condensing
·
Range of six models
·
Compact size - small footprint
·
High modulation - Close load matching (all models down to 11.6kW)
·
108.4% Net efficiency (fully condensing) at 30% part load
·
Boilers consist of several modules giving built-in standby capability
·
Robust cast aluminium heat exchanger
·
Integral commissioning and fault diagnostics
·
Optional flue and system connections for fast installations
·
Meets Building Regulations 2006 (Part L2)
plus II
90 - 310kW
General Data
plus II (90 - 310)
Model F90
F140
F180
F220
F270
F310
Boiler output (condensing)
12.5 - 92.6
12.5 - 136.8
12.5 - 179.3
12.5 - 228.6
12.5 - 280.7
12.5 - 321.5
50/30°C
Boiler output (non-condensing)
11.2 - 89.5
11.2 - 132.2
11.2 - 173.4
11.2 - 221.0
11.2 - 271.3
11.2 - 311.0
80/60°C
Height
1053
Width
695
695
832
968
1102
1236
Depth
695
Flow/Return Connections (BSP)
R2
Gas Inlet (BSP)
R1
1
/
2
Flue Size (mm)
150
150
150
200
200
200
Maximum Working Pressure (bar)
6
Water Content (L)
10.1
14.2
18.3
22.4
26.5
30.6
Approx Dry Weight (kg)
153
182
223
261
301
345
Front (mm)
600
Back (mm)
450*
450*
450
450
450
450
Side (mm)
50 (1 side) & 450 (other side), increase to 600 for side flues.
Boiler
Clearances
Option Kits
Boiler
plus II
Outside sensor kit
*
Tank sensor kit
Remote indication kit
*
Hours run meter(s)
*
BMS (0-10V) kit
*
*Provided as standard
6
*F90 & F140 300 if no rear flue.
New
Model
7
·
Robust cast aluminium heat exchanger
·
In-built commissioning and fault diagnostics
·
Low NOx emissions
·
Volt free contacts supplied as standard
·
Meets Building Regulations 2006 (Part L2)
·
Compact size - small footprint
·
Fully modulating operation down to 20% of output
·
Up to 107.5% nett efficiency (fully condensing)
·
Fits through standard doorways
xtra
80 - 560kW
General Data
xtra (80 - 560)
Model
80
120
160
200
240
280
320
400
480
560
Boiler output (condensing)
25.6 -
25.6 -
32.0 -
47.1 -
51.4 -
55.6 -
75.3 -
107.5 -
116.1 -
118.3 -
50/30°C
82.2
123.4
164.5
207.8
249.4
290.9
329.0
415.6
498.8
581.8
Boiler output (non-condensing)
23.3 -
23.2 -
29.0 -
43.1 -
47.0 -
51.0 -
67.8 -
97.7 -
105.5 -
107.7 -
80/60°C
77.4
116.0
154.8
195.4
234.5
273.6
311.6
390.8
469.0
547.2
Height
1150
Width
600
600
600
600
600
600
1200
1200
1200
1200
Depth
1024
1024
1024
1327
1327
1327
1004
1326
1326
1326
Flow connection (BSP)
R2"
R2"
R2"
R2"
R2"
R2"
80*
80*
80*
80*
Return connection (BSP)
R2"
R2"
R2"
R2"
R2"
R2"
80*
80*
80*
80*
Gas inlet connection (BSP)
R1"
R1"
R1"
R1"
R1"
R1"
R2*
R2*
R2*
R2*
Nominal flue size / concentric (mm)
150
150
150
200
200
200
200
250
250
250
Maximum working pressure (bar)
6
Water content (L)
11.0
14.3
17.5
18.4
24.0
27.2
35.0
36.8
48.0
54.4
Weight (kg)
132
150
168
198
215
233
336
396
430
466
Front (mm)
600
Back (mm)
700
700
700
700
700
700
1000
1000
1000
1000
Side (mm) 450 150 450 150 450 150 450 150 450 150 450 150
450
450
450
450
(LH)(RH) (LH)(RH) (LH)(RH) (LH)(RH) (LH)(RH) (LH)(RH)
*DN flange. Flow, return and gas connection sizes shown are for the optional header kit.
If header kit not used: Flow & Return connections are 2 x R2. Gas connection is 2 x R1.
Extended
Output
Range
Option Kits
Boiler
xtra
80 - 280
320 - 560
Modulating sequence control for
controlling multiple boiler installations
Programmable room thermostat
Tank sensor kit
n/a
BMS control kit (0-10V)
Standard
Boiler
xtra
80 - 280
320 - 560
Outside sensor kit
Room sensor kit
Sequencer DHW sensor kit
Control interface kit
Standard
Boiler
Clearances
8
condensing
·
Natural gas fired condensing boiler
·
Meets Building Regulations 2006 (Part L2)
·
Fully condensing high efficiency 85%
at 80°C, 93% at 60°C flow
·
Compact space saving design
·
Full automatic ignition
·
Advanced electronic controls
Model 48
70
94
116
Boiler output (condensing)
48.83
69.84
93.65
116.25
50/30°C
Boiler output (non-condensing)
44.63
63.84
83.60
106.30
80/60°C
Height
1438
Width
600
Depth
723
846
969
1092
Flow/Return Connections (BSP)
RC2
Gas Inlet (BSP)
RC
3
/
4
RC
3
/
4
RC
3
/
4
RC1
Flue Size (mm)
150
Maximum Working Pressure (bar)
4.5
Water Content (L)
28
36
43
51
Approx Dry Weight (kg)
298
350
442
494
Front (mm)
750
Back (mm)
200
Side (mm)
50
50
50
100
General Data Concord CXC (48 - 116)
Option Kits
Boiler
Remote indication board
Outside sensor
Concord CXC
Concord CXC
48 - 116kW
Boiler
Clearances
9
·
Up to 16% extra heat
·
Compact space saving design
·
Adjustable flue and system connections
·
Low flue and system resistances
·
High insulation levels
·
Fanned or standard versions
·
Suitable for Harrier, Viceroy and Viscount boilers
Model
RCI 300 RCI 300V
RCI 400 RCI 400V
RCI 500 RCI 500V
Output (kW)
180 - 450
230 - 670
390 - 986
Height (mm)
1687
1777
1883
Width (mm)
610
698
830
Depth (mm) (over optional fan)
1156
1250
1376
Flue Size (mm)
300
350
400
General Data GT Condenser (199 - 1096)
Option Kits
Boiler
GT Condenser
Fan version
RCI 300V
RCI 400V
RCI 500V
GT Condenser
199 - 1096kW
The addition of a GT Condenser to the boiler can
provide up to 16% more heat by cooling the flue gases
to gain both sensible and latent heat from condensation.
The lower the system return temperature being fed into
the Condenser the more the gain. It all provides benefits
in lower emissions and lower fuel bills.
This GT Condenser range is suitable for gas fired
boilers only but can be fitted to dual fuel boilers with
suitable flue design. Six models are available to suit
Harrier, Viceroy and Viscount boilers with a boiler output
range suitability from 180kW (614,000 Btu/h) to
986kW (3,364,000Btu/h). Three output models cover
this range and to ensure easy flue installation, each is
available with or without a fan to overcome the flue
pressure loss of the GT Condenser if necessary. A 6 bar
working pressure capability ensures system application
is straight forward.
·
Ultra reliable gas atmospheric boilers
·
High, full and part load efficiencies -
meets Building Regulations 2006 (Part L2)
·
Auto ignition
·
Remote indication kit options
·
CXA/H natural gas or propane CXA P/H (40-100kW)
·
CXA/H is On/Off and CXS/H is High/Low operation
Model 40/H
50/H
60/H
70/H
80/H
90/H
100/H
110/H
120/H
Sections
3
4
4
5
5
6
6
7
7
Output (kW)
40
50
60
70
80
90
100
110
120
Height
1000
Width
600
Depth
750
882
882
1042
1042
1212
1212
1385
1385
Flow/Return Connections (BSP)
RC2
Gas Inlet (BSP)
RC
3
/
4
RC
3
/
4
RC
3
/
4
RC
3
/
4
RC
3
/
4
RC1
RC1
RC1
RC1
Flue Size (mm)
150
150
175
175
200
200
200
250
250
Maximum Working Pressure (bar)
6
Water Content (L)
22
30
30
37
37
45
45
53
53
Approx Dry Weight (kg)
210
265
265
330
330
395
395
490
490
Front (mm)
750
Back (mm)
0
0
0
150
150
300
300
300
300
Sides (mm) 50
50
50
50
50
100
100
100
100
General Data Concord CXA/H S/H (40 - 120)
Option Kits
Boiler
CXA/H
CXS/H
Volt free contacts, boiler run,
overheat & lockout
Down draft thermostat kit
Header kits (available from merchants)
Propane models
Boiler
Clearances
Concord CXA/H S/H
40 - 120kW
10
gas atmospheric
·
Suitable for Concord CXA/H and CXS/H models
·
Multiple installation outputs from 80-720kW
·
All servicing and maintenance from the front of boilers
·
Large clean-out cover for full access to flueways
·
Standard boiler width: 600mm
·
Factory assembled and tested units
·
Sequencer control kit available
·
Remote indication kit options
Model
40/H
50/H
60/H
70/H
80/H
90/H
100/H
110/H
120/H
No. Boilers 2x
80kW
100kW
120kW
140kW
160kW
180kW
200kW
220kW
240kW
3x
120kW
150kW
180kW
210kW
240kW
270kW
300kW
330kW
360kW
4x
160kW
200kW
240kW
280kW
320kW
360kW
400kW
440kW
480kW
5x
200kW
250kW
300kW
350kW
400kW
450kW
500kW
550kW
600kW
6x
240kW
300kW
360kW
420kW
480kW
540kW
600kW
660kW
720kW
General Data Concord Modular (80 - 720)
Sequencer control kit
Concord Modular
80 - 720kW
Option Kits
Boiler
Modular
Sequencer control kit
Outside sensor kit
Mandatory
11
Option Kits
Boiler
CXSi/H
Volt free contacts, alarm & boiler run conditions
·
Ultra reliable gas atmospheric boilers
·
High, full and part load efficiencies -
meets Building Regulations 2006 (Part L2)
·
Auto ignition
·
Remote indication kit options
·
High/Low operation
Model 110/H
120/H
140/H
160/H
180/H
Sections
7
7
8
9
10
Output (kW)
110
120
140
160
180
Height
1000
Width
1107
1107
1230
1353
1476
Depth
1036
1036
1036
1086
1140
Flow/Return Connections (mm)
Flow: DN65 Flange. Return RC2
Gas Inlet (BSP)
RC1
1
/
2
Flue Size (mm)
250
250
250
250
300
Maximum Working Pressure (bar)
6
Water Content (L)
53
53
60
68
76
Approx Dry Weight (kg)
520
520
587
654
721
Front (mm)
700
Back (mm)
200
Side (mm)
100 (not including clearance for side fitted flow header)
General Data Concord CXSi/H (110 - 180)
Boiler
Clearances
Concord CXSi/H
110 - 180kW
12
gas atmospheric
General Data Concord ES/H (140 - 380)
·
High/Low adjustable operation on all models
·
High, full and part load efficiencies -
meets Building Regulations 2006 (Part L2)
·
Assembled or unassembled
heat exchanger availability
·
Robust cast iron heat exchanger
·
Easy to install and service
·
Low return temperature capability
Model 140/H
160/H
180/H
200/H
220/H
260/H
300/H
340/H
380/H
Sections
8
9
10
11
12
14
16
18
20
Output (kW)
140
160
180
200
220
260
300
340
380
Height
1406
1406
1406
1406
1406
1406
1406
1406
1406
Width
970
1058
1146
1234
1322
1498
1674